• Civil Lab Mechanical Lab Engineering Lab Equipments
  • sales@didacticlabequipments.com

Energy Conversion in a wind power station Trainer Model

Energy Conversion in a wind power station Trainer Model

CAT NO: DIDACTICNTE-17-0032

Energy Conversion in a wind power station Trainer Model Description and Tender Specification:

Energy Conversion in a wind power station Trainer Model.
1.19    Technical Description of the Trainer
The Energy Conversion in a wind power station trainer must include the following descriptions or functions:
•    Able to conversion of kinetic wind energy into electrical energy
•    Shall consist different measurements such: wind velocity in front of and behind the rotor, speed of the rotor, voltage and current. function and design of an stand-alone system with a wind turbine
•    determining the power coefficient as a function of tip speed ratio
•    energy balance in a wind power station
•    determining the efficiency of a wind power station
•    the trainer shall be able to conduct experiments under real wind conditions, so that a larger wind generator shall be able to be connected to the control panel.  
1.20    Technical Specification of Trainer
The trainer must include the following technical specifications:
•    trainer for converting kinetic wind energy into electrical energy
•    laboratory-scale wind power station, stand-alone operation
•    axial fan with continuously variable speed (wind velocity)
•    flow straightener for consistent wind conditions
•    generator for converting the kinetic energy into electrical energy
•    accumulator for storing the electrical energy
•    two bulbs as electrical load (consumers)
•    measurement of wind velocity in front of and behind the rotor
•    measurement of rotational speed of the rotor
•    measurement of current and voltage
•    digital displays for the measured values
•    Software for data acquisition via USB under Windows Vista or Windows 7

•    Technical Data:
    Axial fan: max. flow rate: 5m³/s, max. power: 1,5kW
o    Rotor: diameter: 510mm
o    Generator: max. Output: 60W, voltage: 12VDC, max. charging current: 5A
o    Accumulator: voltage: 12VDC, capacity: 8Ah
o    Electrical load (bulbs): voltage: 12VDC, power: 55W each
o    Measuring ranges: wind velocity: 0,3...50m/s,, speed: 0...3.000min-1,  voltage: 0...20VDC, current: 0...35A
o    Dimensions and Weight: LxWxH: 2.610x870x1.645mm (experimental section), LxWxH: 1.520x790x1.760mm (control unit), Total weight: approx. 410kg
o    Required for Operation: 400V, 50Hz, 3 phases or 230V, 50Hz, 3 phases
o    Scope of Delivery:
    1 experimental section
    1 control unit
    1 multimeter
    1 CD with software + USB cable
    1 set of instructional material

1.21    Figurative description of the Trainer System
An equivalent resemblance of the solar thermal energy Trainer system is indicated in Figure 7.

Figure 7: Equivalent figurative description of the Energy Conversion in a wind power station trainer

Support